INPUT
Nominal voltage208/220/230/240Vac
Input voltage range110~286Vac
Frequency range40~70Hz (50/60Hz Auto-Sensing)
Power factor≥0.99
Max.voltage:220V:+25% (Optional+10%,+15%,+20%) 230V:+20% (Optional+10%,+15%,+20%)
Bypass voltage range240V:+15% (Optional+10%)
Min.voltage:-45% (Optional-20%,-30%)
OUTPUT 
Output voltage208/220/230/240Vac
Power factor0.9
Voltage regulation±1%
Output frequencyLine Mode±1%/±2%±/±4%/±5%/±10% of the rated frequency (Optional)
Bat. Mode(50/60±0.1%)Hz
Crest factor3:01
Harmonic distortion (THDv)≤2% Linear load
≤5% Non linear load
Transfer timeAC mode to Bat.Mode0ms
Inverter to Bypass0ms
Output waveformPure Sinewave
OverloadLine ModeLoad≤110% last 60min; ≤125% last 10min; ≤150% last 1min; >150% turn to bypass mode immediately
Bypass Mode40A (Breaker)63A (Breaker)
Efficiency94%
BATTERY 
Battery voltage±96/±108/±120Vdc (Adjustable)±120Vdc±96/±108/±120Vdc (Adjustable)±120Vdc
Capacity (Standard unit)9Ah/12V (7Ah/12V optional)
Typical recharging time6~8 hours (to 90% of full capacity)
Charging current1A (Standard unit); Long run unit Max.current 10A (Charging current can be set according to battery capacity)
INDICATORS
LED displayLine mode,Bat.mode,ECO mode,Bypass mode,Battery low voltage,Overload & UPS fault
LCD displayInput voltage,Input frequency,Output voltage,Output frequency,Load percentage,
Battery voltage,Inner temperature& Remaining battery backup time
ALARM 
Battery modeBeeping every 4 seconds
Battery lowBeeping every second
OverloadBeeping twice every second
FaultContinously beeping
PHYSICAL
Dimension W x D×H (mm)440 x 625 x 86.5
Net weight (kg)1618
ENVIRONMENT 
Operating temperature0℃~40℃
Storage temperature-25℃~55℃
Humidity range20~95%RH @ 0~40℃ (Non condensing)
Altitude<1500m,derating required when>1500m
Noise level<55db at 1 Meter<58db at 1 Meter
STANDARDS 
SafetyIEC/EN62040-1,IEC/EN62477-1
EMCIEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8

 

â– High power density
â– LCD supports Rack/Tower convertible design
â– N+X parallel redundancy, support a maximum of 4 units in parallel
â– Online double conversion with full digital control
â– Optimization battery group, the quantity of battery:16/18/20pcs (Settable)
â– Wide input voltage range:110~286Vac
â– Wide input frequency range
â– Generator compatible
â– ECO mode operation for energy saving
â– Self-testing when UPS startup
â–  communication interfaces: RS232/USB/EPO(Relay card/SNMP card optional)
â– Parallel kit default
â– Maximum charging current up to 10A
â– Cold start
â– Intelligent fan speed regulation
â– Multiple protection functions: short-circuit, overload, overheat, battery overcharge and over-discharge, output low voltage and fan fault alarm